Product Description
A nanofiltration (NF) membrane is a type of semi-permeable membrane that filters water and other solutions based on size and charge. It falls between ultrafiltration (UF) and reverse osmosis (RO) in terms of pore size, typically ranging from 1 to 10 nanometers. NF membranes are used to remove divalent ions, some larger organic molecules, and other contaminants while allowing smaller molecules like water and some salts to pass through.
Puri-guard has NF30, NF40, NF60 and NF90 based on different salt rejection and using application. All have its single page to guide you how to choose your right models.
NF60 Membrane Feature
- High selective separation
- Low operating cost
- Long-term stable operation
NF60 Application
- Material concentration and separation
- Separation salt
- Reuse of reclaimed water
- Almost (zero) discharge filed
Hot Tags: nf 60 membrane, China nf 60 membrane manufacturers, suppliers, factory, nf membranes, nf membrane water purification system, Reverse Osmosis Nanofiltration, nf 4040 membrane, nf 8040 membrane, nanofiltration ro membrane
performance Datas
|
Model |
Permeate flow |
Salt rejection (%) |
Membrane area (ft²/m²) |
Testing pressure (psi/MPa) |
|
PURI-NF60-4040 |
1500 (5.7) |
97.5 |
85 (8.0) |
70 (0.48) |
|
PURI-NF60-8040FR |
8000 (30.3) |
98.5 |
400 (37.0) |
110 (0.76) |
|
Testing condition for industrial 8040: 2000ppm, MgSO4 25℃, pH=7.5-8, 15% recovery |
||||
NF 60 membrane Operation Condition
Maximum Operating Pressure 41 bar (600 psi) for NF60
Maximum Operating Temperature 45ºC (113ºF)
Maximum Pressure Drop per Element 1.0 bar (15 psi)
pH Range, Continuous Operation 3-10 Nanofitration NF60
pH Range, Chemical Cleaning 2-12 for NF60
Maximum Feed Silt Density Index (SDI15) 5.0
Free Chlorine Tolerance < 0.1ppm
Max. feed water flow ------ 75gpm (17m3/h)