Product Description
Puri-guard® 3012 RO membrane has its main model 3012-300 and 3012-400, based on different customer's request and different area requirement, choose the right one.
For the higher flow , we also supply 3012-500 and 3012-600.
in same time, 3013 is also very popular , 3013-400/600/800/1000
The product is generally suitable for the desalination treatment of raw water with a salt content of less than 1000mg/L, with the characteristics of high desalination rate and low operating pressure, and is mainly used in small direct drinking water devices at home or office places.
Products Applications
- Large household RO syetems (big family )
- Tankless RO systems (400-800 GPD systems)
- Small commercial use : cafes , restarats , offices
why choose us
Puri-guard® Your Pure Trust

why choose our products
- Based on different using condition and requirements , we supply many models ,3012-300, 3012-400,3012-500 ,3012-600, 3013-400, 3013-600,3013-800,3013-1000.
- Higher rejection for worse feed water or higher flow for good feedwater like Europe , all available .
- Quality guarantee , choose the right and quality sheet to guarantee its delievry quality .
FAQ
1. Dry or Wet type, which is better?
Dry membrane normally understands as easy-keeping.
Wet type mainly understands as quality and performance guaranteed.
Based on nowadays quality control, most of people choose dry type.
2. Wet membrane protection liquid knowledge?
Wet membrane components are strictly tested before leaving the fatory, and 1.0% sodium bisulfite (in winter, 10% glycerol antifreeze is added) solution for storage treatment, and then vacuum packaging, outer packaging for cardboard boxes. To prevent microbial growth during short-term storage, transportation, and system standby, it is recommended to soak components with a protective solution (prepared with RO production water) containing 1.0% sodium bisulfite (food grade).
The water produced in the first hour of operation should be discharged.
In the storage and operation, it is prohibited to add any chemical agent that has an impact on the membrane element. If such chemical agent is used in violation, Hangzhou Puri-guard will not bear all the consequences arising therefrom.
Hot Tags: 3012 ro membrane, China 3012 ro membrane manufacturers, suppliers, factory, polyamide composite ro membrane, 80 gpd ro membrane, High Flow RO Membrane, ro membrane filtration system, ro membrane industrial system, 80 GPD
Products Parameters
|
Puri-guard® Element |
Permeate Flow GPD (m3/d) |
Testing Pressure |
Salt Rejection (%) |
|
|
psi/MPa |
||||
|
3012-300 |
300 (1.14) |
90 (0.62) |
97.5 |
|
|
3012-400 |
400 (1.51) |
90 (0.62) |
97.5 |
|

1. Permeate flow and salt (NaCl) rejection based on the following standard test conditions. 250 ppm softened tap water, 77°F (25°C), pH 7.5, 15% recovery and the specified applied pressure.
2. Minimum salt rejection: 96%.
3. Single membrane element production flow may vary ±20%.
Operating limit
|
Diaphragm type |
Polyamide Composite Membrane |
|
Maximum operating temperature |
113℉ (45℃) |
|
Maximum operating pressure |
150 psi (10 bar) |
|
pH range, continuous operation |
3-10 a |
|
Maximum Influent SDI |
5 |
|
Free chlorine tolerance |
<0.1 ppm b |
a. When pH >10, the maximum allowable temperature for continuous operation is 95℉(35℃).
b. Under certain conditions, the presence of free chlorine and other oxidants will lead to premature failure of membranes. Therefore, it is recommended that the membrane be pretreated to remove residual free chlorine before water comes into contact with membranes.